Common Questions
We offer you:
24-hour service on the entire range
Commissioning and staff training for customers
Remote maintenance and support in case of problems
Emergency service
Short procurement routes for spare parts
Maintenance at the customer's site
Maintenance contracts
The machine does not open (conventional control):
Use the display to check whether the machine is still under vacuum.
Move the vacuum breaker to the open position. Wait approx. 12 seconds (release time relay).
If the ventilation time takes longer than 12 seconds, check that the filter on the base is not blocked and replace it.
If the machine still does not open, please contact PC Laborsystem GmbH.
The machine does not open (PLC with touch screen control):
Systems controlled by Siemens PLC open when the pressure sensor has reached the safety limit value.
The mixer does not start:
The proximity switch may have received an incorrect signal. Open the mixer by about 5 cm to reset the safety circuit and
Check that the proximity switch on the vacuum hood is positioned correctly.
Machine open LED on the proximity switch off, machine closed LED on.
The measuring range is between 1-3mm.
Start the mixer as usual.
If the forced cooling fan starts but not the mixer, open the control box to check the status of the frequency converters and document any error codes.
If the machine still does not start, please contact PC Laborsystem GmbH.
The machine does not switch on:
Ensure that the system is connected to a suitable power source.
Turn the main switch to the ON position. Check that all fuses in the control cabinet are ON.
Ensure that all safety circuits in the control box are set to ON.
The direction of rotation of the can/boiler is incorrect:
If the direction of rotation is not clockwise, swap 2 wires on the input plug after you have switched off the mixer and disconnected disconnected from the mains.
Diverse
Disperser
Butterfly / Butterfly
Kneading / Kneading
Disperser / Kneading
Rotor / Stator
Schneckenradzuführer
EA_1
Hercules
Labotop
OM_1
OM_2
2 x Butterfly Tools
Single Butterfly Tool
Single Dissolver Tool
TKK_2
Abfullen mit Vakuum
MT_1
MT_2
PM_1
VR_1
3DM_1
SE_1
VR_2
ZL_1
AK_1
ZL_2
3DC
BH_1
BH_2
HM_1
MT_3
SIC_1
TKK_1
TR_1
W_3
PM_2
W_1